| Jamo Waterproof Product Specifications |
PRODUCT DESCRIPTION
Ready-to-use, elastomeric waterproofing and
anti-fracture membrane for use prior to the installation of tile, stone,
vinyl or rubber tile, strip wood or parquet. Easy to apply, it goes on by
brush or roller producing a continuous moisture barrier with outstanding
adhesion to concrete slabs, concrete block, cement backerboards and
exterior grade plywood. Reduces crack transmission in ceramic tile or
stone floors. Meets ANSI A118.10 for waterproofing membranes. For all
interior or exterior commercial and residential tile installations.
AREAS OF USE
Concrete,
Cement backerboards,
WonderBoard®
Exterior grade
plywood
USE UNDER THESE FLOOR
COVERINGS
Ceramic
tile
Stone
Vinyl or rubber tile
Stripwood or Parquet
LIMITATIONS
Do not apply to surfaces that may go below 40° F (4°
C) during the first 72 hours after application, over wet surfaces or
surfaces subject to hydrostatic pressure. Do not use to bridge or cover
over existing expansion, control, construction, cold or saw-cut joints.
Not for use as an adhesive. Do not use as a wear surface. Membrane must be
covered with tile or other protective surface.
SURFACE PREPARATION
Must be in accordance with the proper ANSI
specifications, depending on the method chosen. All exterior and wet areas
are to have proper sloping to drains. All surfaces must be structurally
sound, clean, dry and free from contaminants that would prevent a good
bond. Newly prepared concrete surfaces should be smooth and have a
troweled or brushed finish. Existing surfaces should be smooth and level
and all defects repaired. All cracks in
concrete up to 1/8" (3 mm) should be pre-filled with membrane prior to
application. Gaps between plywood sheets and where they meet walls or
drains should also be pre-filled with membrane. Cracks in excess of 1/8"
(3 mm) should be treated as expansion joints.
PROTECTION
If tile is not going to be set immediately after curing,
LevelQuik Waterproofing & Anti-Fracture Membrane should be protected
from rain and inclement weather for 72 hours after application. If delays
longer than 72 hours are expected, cover with felt paper. Care should be
taken to prevent membrane from becoming soiled or punctured during and
after application.
APPLICATION
Dampen all porous surfaces. Heavily pre-coat all
edges, corners, and where floors and walls meet extending it 6" (15.2
cm) on either side. Use a brush or a 1/4" or 3/16" (6 mm or 5
mm) V-notched trowel. If using a trowel, key-in the material, then flatten
the ridges. Then apply a continuous, even film with overlapping strokes
using a 3/4" (19 mm) rough textured synthetic roller. After the first
coat has dried about 1-1/2 to 2 hours, check for voids or pinholes. Fill
any voids with additional material and apply a second coat at right angles
to the first. The dried coating needs to be a minimum of 1/32" (.8
mm) thick [3/64" (1.2 mm) when wet] and should never exceed 1/8"
(3 mm) thickness.. |
DRYING TIME
24 hours. A water
test can be conducted 72 hours after application if required. CLEAN-UP
Clean tools and hands
with water before material dries.
PHYSICAL PROPERTIES
| Packaging: |
1 gallon (3.78 L) and 5
gallon (18.9 L) pails. |
| Storage: |
Keep from
freezing. |
SAFETY
Wear rubber gloves and
eye protection. Avoid eye contact. If eye contact occurs, flush with water
for 15 minutes and call a physician. Wash thoroughly after handling.
KEEP OUT OF REACH OF CHILDREN. DO NOT TAKE INTERNALLY.
Warning: This product contains one or more chemicals known to the State of
California to cause cancer. TECHNICAL DATA
Meets ANSI
A118.10 for load bearing, bonded, waterproof membranes for thin-set
ceramic tile and dimensional stone installations.
| |
LevelQuik
Waterproofing
&
Anti-Fracture Membrane |
| Pot Life |
Indefinite |
| Initial Set, ASTM C191 @
70° F (21° C) |
1 1/2 - 2 hours |
| Drying time before
floor covering installation |
24 hours |
| ANSI 118.10 Sect # |
|
Fungus and
Micro-Organism
Resistance (4.2) |
Passes |
| Seam Strength (4.2) |
10.2 lbs./inch width
(4.6
kg/2.54 cm) |
| Breaking Strength (4.3) |
401 psi (28.2
kg/cm2) |
| Dimensional Stability (4.4) |
0.70% |
| Waterproofness (4.5) |
Passes |
| Shear Strength |
|
| 7-day dry cure
(5.3) |
200 psi (14
kg/cm2) |
| 7-day water immersion
(5.4) |
150 psi (10.5
kg/cm2) |
| 4-week dry cure
(5.5) |
355 psi (25
kg/cm2) |
| 12-week dry cure
(5.6) |
389 psi (27.3
kg/cm2) |
| 100-day water immersion
(5.7) |
194 psi (13.6
kg/cm2) |
| % Elongation ASTM
D-638 |
|
| 7-day dry |
580 psi (40.8
kg/cm2) |
| 14-day dry |
650 psi (45.7
kg/cm2) |
| 21-day dry |
562 psi (39.5
kg/cm2) |
| 7-day dry/7-day
wet |
693 psi (48.7
kg/cm2) |
| 7-day dry/14-day
wet |
738 psi (52
kg/cm2) |
| 7-day dry/21-day
wet |
657 psi (46.2
kg/cm2) |
COVERAGE
1 gallon (3.78 L) pail: 35 - 40 sq. ft. (3.25 - 3.7
m2) at 3/64" (1.2 mm)
thickness
5 gallon
(19.9 L) pail: 175 - 200 sq. ft. (16.2 - 18.5 m2) at 3/64"
(1.2
mm)
thickness
|